Adding PIOLINK WEBFRONT-K via Syslog

Purpose

This guide explains how to forward PIOLINK WEBFRONT-K web application firewall logs to Logsign USO over syslog and what Logsign does with them. The integration covers the WAF security log (access control, scanner, credit card information protection and credential stuffing detections), invalid HTTP protocol events, Web Manager logins, settings read and change records, configuration file and webpage integrity checks, e-mail alarm failures, and the operating system lines of the appliance (CRON, su, sudo and SSH).

Prerequisites

  • A WEBFRONT-K administrator account that is allowed to change the syslog settings of the appliance.
  • Network connectivity from the WEBFRONT-K appliance to the Logsign USO collector on your syslog port (TCP or UDP 514 by default).
  • The Logsign user account that will add the data source needs access to Settings > Data Collection.
  • A Logsign USO release that includes the PIOLINK WEBFRONT-K plugin. If PIOLINK is not in the vendor list, contact Logsign support.

Step 1: Forward WEBFRONT-K logs to Logsign

On the WEBFRONT-K appliance, add the IP address of the Logsign USO collector and the syslog port as a remote syslog server. Menu names differ between WEBFRONT-K releases, so use the PIOLINK documentation for your version to find the syslog server settings. Enable the security, audit and system logs that you want to see in Logsign.

Logsign recognizes two message templates. Both start with the WEBFRONT-K timestamp, followed by the year and the severity in parentheses:

  • The vendor default template, separated by spaces, with the syslog priority after the year: Nov 9 14:48:50 2026 <133> (notice) rest: [WEBFRONT/0x004F6402] ...
  • A custom template where the same values are separated by +: +Nov 19 14:46:36+2026+(warning)+log_processor: [WEBFRONT/0x00721004] ...

Do not add a host name to the template and do not switch the output to CEF, JSON or another key-value format. Messages in those formats are not recognized by this integration.

Step 2: Add the data source in Logsign USO

Open the Logsign USO web interface and click + Device under Settings > Data Collection. Choose Syslog as the collection method, select PIOLINK as the vendor and WEBFRONT-K as the product, and enter the IP address of the WEBFRONT-K appliance as the host. Repeat this for every appliance that sends logs. Click Save. Once the appliance starts sending, events appear under Search with EventSource.Type Security System and EventSource.Category Web Application Firewall.

Supported log types

WEBFRONT-K writes a message code in the form [WEBFRONT/0x........] at the start of most messages. Logsign stores this code in Event.VendorID and uses it, together with the block value of security logs, to classify the event:

Log type Process.Name EventMap (Context / Type / SubType)
Application Access Control log_processor Security / Access Control / Block (block="yes") or Info (block="no")
Scanner log_processor Security / Scan / Detect (block="yes") or Info (block="no")
Credit Card Information Protection (request and response) log_processor Security / DLP / Block (block="yes") or Detect (block="no")
Credential Stuffing log_processor Security / BruteForce / Block (block="yes") or Detect
Any other security log code log_processor Security / Attack / Block (block="yes") or Detect
Invalid HTTP protocol apss Security / Attack / Info
Web Manager login rest Identity / User / Login (the request step is Identity / User / Request)
Web Manager session extend rest Identity / User / Info
Settings read rest, statistics_db, wsyncd and others System / Configuration / Info
Settings change int_chk, auto_blacklist and others System / Configuration / Change
Configuration file integrity int_chk Security / FileIntegrity / Info
Webpage integrity check start and end wsyncd System / Scan / Start and System / Scan / End
E-mail alarm failure send_email_processor.py System / Service / Error
SSH login accepted sshd-session Identity / User / Login
Other appliance OS lines (CRON, su, sudo, sshd) program name of the line System / Operation / Info

A message code that is not in the classification table and is not a security log stays on System / Operation / Info (70201). Use Event.VendorID and Event.Message to filter these events.

Field mapping

The text before the parenthesis is written to Event.Message. For security logs, the part of that text before " - " is also written to Event.Category (for example Application Access Control). The key="value" block in the parenthesis is mapped as follows:

WEBFRONT-K key Logsign field
log_idEvent.ID
blockEvent.Action (yes becomes Block, no becomes Detect)
app_id, app_nameApplication.ID, Application.Name
security_id / policy_id, security_namePolicy.ID, Policy.Name
src_ip, src_port, client_ip, clientSource.IP, Source.Port
dest_ip, dest_port, serverDestination.IP, Destination.Port
hostURL.Domain (without the port) and URL.URI (host and URL)
url, url_param, protocolURL.Path, URL.Query, URL.Scheme
forwarded_forSource.XForwardedIP (first address)
sigid, sig_warning, owaspSignature.ID, Threat.Level, OWASP.Category
user, user_type, user_agentSource.UserName, Source.UserType, Source.UserAgent
desc / msg, reason, resultEvent.Description, Event.Reason, Event.Result
name, path, integrityFile.Name, File.Path, Event.Status

The severity in parentheses in the message header (for example (warning) or (notice)) becomes the event severity. The program name and PID in the header go to Process.Name and Process.PID.

Notes and limits

  • Credit card numbers (data and raw_data) and the Web Manager session token are not written to any Logsign field, including Event.Message.
  • Values that contain commas, such as browser user agents, are kept whole.
  • WEBFRONT-K cuts long lines at its syslog size limit. Such lines are still parsed, but keys after the cut point are missing from the event.
  • Empty values and the value none are not written to fields. A sigid of 0 leaves Signature.ID empty.
  • Event time comes from the WEBFRONT-K timestamp and year in the message header.

Verification

After both sides are saved, a Web Manager login is enough to check the integration end to end.

  • In Logsign USO, open Settings > Data Collection and confirm that the WEBFRONT-K source is receiving data.
  • Log in to the WEBFRONT-K Web Manager. In Search, look for events with Vendor PIOLINK and Product WEBFRONT-K. The login should appear with EventMap Identity / User / Login, Event.VendorID 0x004F6402 and your user name in Source.UserName.
  • Request a URL that a WEBFRONT-K security policy blocks. The event should show Process.Name log_processor, Event.Action Block and the policy and application names in Policy.Name and Application.Name.
  • If the source is receiving data but no events show Vendor PIOLINK, the messages are not in a template this integration recognizes. Check that the messages start with the timestamp, the year and the severity in parentheses, as shown in Step 1, and that nothing on the way rewrites the message.
Was this article helpful?
0 out of 0 found this helpful

Articles in this section

See more
Become a Certified Logsign User/Administrator
Sign-up for Logsign Academy and take the courses to learn about Logsign USO Platform in detail. Enjoy the courses, and get your badges and certificates. In these courses, you'll learn how to use Logsign in your work and add value to your career.
Visit Our Blog
Our Logsign USO Platform illustrate our expertise. So do the blog. Through our blog posts, deepen your knowledge on various SecOps topics or get updated about important news & modern approaches for cybersecurity. Get into the habit of reading valuable information provided by Logsign. Be a step ahead.