Switch Configure
We need to connect to the Huawei switch with telnet or ssh. Then log in with the administrator account.
Switch to global configuration mode.
system-view
Enter the IP address of your Logsign USO server. On Huawei you should send syslog over UDP.
info-center loghost <Logsign USO IP> facility local7
Here local7 determines in which facility area the logs will be sent. Logsign USO side can filter according to this field.
Specify the log level you want to send. For example, you can filter to send only critical and above logs.
info-center source default channel loghost log level informational
After doing these operations, you can send the save command from the shell and start adding sources from Logsign USO.
Log Format Sample
<Date and Time> <Device Name> <Severity Level> <Module/Category>: <Message>
Device Add
To make Huawei switch integration, it will be enough to know the ip address that the switch has. When you fill in and save the necessary steps from the source addition screen with Syslog(514), the integration of your product will be completed and log flow will start.
Just fill in the Ip section and write the name you want to give to the source.