Sonicwall Integration

Sonicwall Configuration :

Before begin to configure the Logsign system, we need to setup Sonicwall properly.

1. Login on your Sonicwall system :
 
 
2. On the left side panel, click on "Log" → "Syslog" then click on "Add" :
 
 

3. A popup window will be shown asking you about :

  • IP : The IP address of the remote Syslog server.

  • Port : Default is 514.

4. Now navigate to "Log" → "Categories" and select the following :

  • Logging Level: "Informational"

  • Alert Level: "Alert"

  • Log Redundancy: "60"

  • Alger Redundancy: "900"

  • Then check on the "Syslog" checkbox.

Logsign Configuration :

1. Go to "Settings" → "Device List" then click on "Add new source" :
 
 
2. Select "SYSLOG" :
 
 
3. Select "Sonicwall" :
 
 
4. Select "Firewall" :
 
 

5. Provide the following information :

  • IP : The IP address of the remote Syslog server.

  • Description : "Sonicwall"

  • Tag : "Sonicwall"